24/7 HVAC & Plumbing Repair & Replacement in Mason, MI
24/7 Emergency Service
HVAC emergencies happen when you least expect them. Contact the professionals at Vredevoogd to take care of the job if you’re dealing with a heating or cooling emergency. We have the necessary skills and tools to fix your system so you can safely use it once again. Call the team at 844-482-2365 to get emergency HVAC services in Michigan.

Expert HVAC, Plumbing & Generator Services in Mason

Mason is a beautiful place to live in the plains and rivers of the Great Lakes region. The area draws a diverse population of homeowners of every kind, and the team at Vredevoogd is always here to serve them. With over 60 years of experience, our licensed and insured technicians have the skills to provide comprehensive HVAC, plumbing, and generator services that prioritize your comfort and convenience. Plus, with our same-day services, you can trust that we’ll be here when you need us most!

Contact Vredevoogd today to schedule HVAC, plumbing, or generator services for your Mason home! 

Vredevoogd technician speaking with a Michigan homeowner

24/7 Emergency HVAC Services

At Vredevoogd, we understand that heating and cooling issues can impact your comfort and safety. That’s why we’re proud to offer 24/7 emergency HVAC services to diagnose and resolve breakdowns quickly. Whether you lose heat on the coldest day of the year or are stuck in the sweltering heat, our team will ensure you receive the urgent repairs you need.

Heating Services

When temperatures drop below freezing, turn to Vredevoogd for comprehensive heating service for your furnaces and boilers. From installation and replacement to repairs and maintenance, our expert services help ensure you have an efficient and effective heating system to keep your house at the perfect temperature throughout the coldest months.

Air Conditioning Services

With cooling services from Vredevoogd, you can keep your house cool and comfortable throughout the summer heat. Our technicians have the experience and training to provide installation, replacement, repair, and maintenance for a variety of system types, including central AC, ductless mini-splits, and heat pumps.

Air Quality Services

By prioritizing the quality of your home’s air, you can improve your comfort and your HVAC’s energy efficiency. Vredevoogd’s air quality services can help ensure that the air you breathe daily is clean, fresh, and free of contaminants from various products and services. Plus, we offer humidifier services to help restore your home’s moisture balance.

Join Our Comfort Club Today

Streamline your home’s HVAC maintenance with our Comfort Club membership! As a member, you’ll receive regular tune-ups, priority scheduling, and exclusive discounts. This ensures you get all the benefits of preventative maintenance, including improved performance, reduced breakdowns, and an extended lifespan for your equipment. 

Dependable Plumbing Services

For all your plumbing needs in Mason, trust the experts at Vredevoogd. We offer various plumbing services, including installation, replacement, repair, and maintenance, to keep your entire plumbing system operating at peak performance. Plus, our team provides services for water heaters, sump pumps, drain cleaning, and sewer lines.

Trustworthy Generator Services

When storms and extreme weather result in power outages, you can keep your lights on with a whole-home generator from Vredevoogd. We offer a variety of generator services, including installation and repair, to ensure that you always have reliable backup electricity for your Mason home. Our systems have enough power to run your home’s most critical systems, like HVAC, security, medical equipment, and more. 

Schedule With Vredevoogd in Mason, MI, Today

At Vredevoogd, we’ve provided peace of mind for over 60 years. Our licensed, insured, and background-checked technicians offer the highest quality care for your HVAC, plumbing, and generators. Plus, with our free estimates on replacements and available financing, we’re here to ensure you receive superior service at a great value!

Call Vredevoogd today for home services in Mason, and check out our deals and promotions for even more ways to save!

Recent Jobs and Reviews in Mason, MI

Rated 5.0 out of 5 stars based on 3 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and appreciation. Customers consistently express gratitude for the professionalism, efficiency, and knowledge demonstrated by the service team. Recurring themes include technicians being described as friendly, polite, and courteous, creating a welcoming and comfortable service experience. Many reviewers emphasize the thoroughness of the work performed, with technicians taking time to explain issues clearly, provide detailed assessments, and ensure customers understand the repairs or maintenance being conducted. The communication skills of the team stand out prominently, with customers appreciating transparent explanations and demonstrations of completed work. Efficiency and promptness are frequently highlighted, with customers noting quick problem identification and timely completion of jobs. The professionalism of the service providers is a dominant positive trend, with reviewers consistently praising the knowledgeable approach and respectful demeanor of technicians. Several customers express strong loyalty and intent to continue using the service, with some specifically noting superior diagnostic capabilities compared to competitors. The tone throughout is one of trust, satisfaction, and genuine appreciation for quality workmanship and excellent customer service. Overall, these reviews paint a picture of a highly competent, customer-focused team that consistently delivers reliable and professional HVAC and plumbing services.

Job Locations and Reviews

Mason, MI - Responded to no cooling complaint at single family residence. Upon arrival, inspected HVAC system located in basement utility area including air handler, ductwork, refrigerant lines, and associated components. Documented equipment installation and current system configuration with photos for service records.
Nathan H.
Nathan H. Checked in
Responded to no cooling complaint at single family residence. Upon arrival, inspected HVAC system located in basement utility area including air handler, ductwork, refrigerant lines, and associated components. Documented equipment installation and current system configuration with photos for service records.
Mason, MI 48854
Responded to sump pump discharge issue where water was spraying back into the basement through a failed PVC pipe connection at the sump pit. Upon inspection, identified deteriorated connection fittings on the discharge line that had been leaking for approximately two months. Repaired the compromised PVC connection point at the sump basin, ensuring proper seal and secure fitting to prevent water from re-entering the basement area. Verified discharge line integrity from interior sump pit through exterior termination point at foundation, confirming proper drainage flow away from structure. Tested system operation under full pump cycle to confirm leak elimination and proper water evacuation. Documented existing installation configuration including discharge routing and exterior drainage connection. System restored to full operational status with no further water intrusion into basement area.
Responded to sump pump discharge issue where water was spraying back into the basement through a failed PVC pipe connection at the sump pit. Upon inspection, identified deteriorated connection fittings on the discharge line that had been leaking for approximately two months. Repaired the compromised PVC connection point at the sump basin, ensuring proper seal and secure fitting to prevent water from re-entering the basement area. Verified discharge line integrity from interior sump pit through exterior termination point at foundation, confirming proper drainage flow away from structure. Tested system operation under full pump cycle to confirm leak elimination and proper water evacuation. Documented existing installation configuration including discharge routing and exterior drainage connection. System restored to full operational status with no further water intrusion into basement area.
Jason M.
Jason M. Checked in
Responded to sump pump discharge issue where water was spraying back into the basement through a failed PVC pipe connection at the sump pit. Upon inspection, identified deteriorated connection fittings on the discharge line that had been leaking for approximately two months. Repaired the compromised PVC connection point at the sump basin, ensuring proper seal and secure fitting to prevent water from re-entering the basement area. Verified discharge line integrity from interior sump pit through exterior termination point at foundation, confirming proper drainage flow away from structure. Tested system operation under full pump cycle to confirm leak elimination and proper water evacuation. Documented existing installation configuration including discharge routing and exterior drainage connection. System restored to full operational status with no further water intrusion into basement area.
Mason, MI 48854
Provided estimate for water heater replacement in unfinished basement utility area. Assessed existing white tank-style water heater with current plumbing configuration including white PVC venting system, copper supply lines, and recirculation pump with electronic controls. Documented existing installation featuring ScaleBlaster water conditioning system, gray wall-mounted HVAC or water treatment unit, and black circulation pump at base of current heater. Photographed complete plumbing layout including complex PVC piping arrangements with multiple elbows and joints, aged copper piping with visible patina, and blue electronic controller for pump system. Reviewed accessibility within exposed wooden framing and evaluated requirements for new water heater installation to match existing connections and maintain proper venting through current PVC system.
Provided estimate for water heater replacement in unfinished basement utility area. Assessed existing white tank-style water heater with current plumbing configuration including white PVC venting system, copper supply lines, and recirculation pump with electronic controls. Documented existing installation featuring ScaleBlaster water conditioning system, gray wall-mounted HVAC or water treatment unit, and black circulation pump at base of current heater. Photographed complete plumbing layout including complex PVC piping arrangements with multiple elbows and joints, aged copper piping with visible patina, and blue electronic controller for pump system. Reviewed accessibility within exposed wooden framing and evaluated requirements for new water heater installation to match existing connections and maintain proper venting through current PVC system.
Chris J.
Chris J. Checked in
Provided estimate for water heater replacement in unfinished basement utility area. Assessed existing white tank-style water heater with current plumbing configuration including white PVC venting system, copper supply lines, and recirculation pump with electronic controls. Documented existing installation featuring ScaleBlaster water conditioning system, gray wall-mounted HVAC or water treatment unit, and black circulation pump at base of current heater. Photographed complete plumbing layout including complex PVC piping arrangements with multiple elbows and joints, aged copper piping with visible patina, and blue electronic controller for pump system. Reviewed accessibility within exposed wooden framing and evaluated requirements for new water heater installation to match existing connections and maintain proper venting through current PVC system.
Mason, MI 48854
Installed shut-off valve on dedicated gas line to stove in basement utility area and prepared connection point for new stove installation. Work completed on copper gas piping system with all connections tested and verified for proper operation and safety.
Installed shut-off valve on dedicated gas line to stove in basement utility area and prepared connection point for new stove installation. Work completed on copper gas piping system with all connections tested and verified for proper operation and safety.
Nicholas T.
Nicholas T. Checked in
Installed shut-off valve on dedicated gas line to stove in basement utility area and prepared connection point for new stove installation. Work completed on copper gas piping system with all connections tested and verified for proper operation and safety.
Mason, MI 48854
Responded to third service call for air conditioning system running continuously, requiring thermostat setting of 76°F to cycle off. Upon inspection, discovered significant disconnected ductwork in attic space, which was causing substantial conditioned air loss and preventing proper system cycling. Documented ductwork separation with photos showing metal duct connections pulled apart from mounting brackets and structural supports. Addressed customer concerns regarding previous capacitor diagnosis, confirming that disconnected ductwork was the primary issue affecting system performance rather than electrical components. Explained how air loss from separated ducts created continuous cooling demand, preventing thermostat satisfaction at normal temperature settings.
Responded to third service call for air conditioning system running continuously, requiring thermostat setting of 76°F to cycle off. Upon inspection, discovered significant disconnected ductwork in attic space, which was causing substantial conditioned air loss and preventing proper system cycling. Documented ductwork separation with photos showing metal duct connections pulled apart from mounting brackets and structural supports. Addressed customer concerns regarding previous capacitor diagnosis, confirming that disconnected ductwork was the primary issue affecting system performance rather than electrical components. Explained how air loss from separated ducts created continuous cooling demand, preventing thermostat satisfaction at normal temperature settings.
Chris J.
Chris J. Checked in
Responded to third service call for air conditioning system running continuously, requiring thermostat setting of 76°F to cycle off. Upon inspection, discovered significant disconnected ductwork in attic space, which was causing substantial conditioned air loss and preventing proper system cycling. Documented ductwork separation with photos showing metal duct connections pulled apart from mounting brackets and structural supports. Addressed customer concerns regarding previous capacitor diagnosis, confirming that disconnected ductwork was the primary issue affecting system performance rather than electrical components. Explained how air loss from separated ducts created continuous cooling demand, preventing thermostat satisfaction at normal temperature settings.
Mason, MI 48854
Responded to water leak emergency caused by screw penetration through copper water line in interior wall. Cut access opening in textured wall to expose damaged pipe section, verified leak location, and assessed extent of damage to surrounding wall materials. Repaired compromised copper plumbing line and restored water service to home.
Responded to water leak emergency caused by screw penetration through copper water line in interior wall. Cut access opening in textured wall to expose damaged pipe section, verified leak location, and assessed extent of damage to surrounding wall materials. Repaired compromised copper plumbing line and restored water service to home.
Albert G.
Albert G. Checked in
Responded to water leak emergency caused by screw penetration through copper water line in interior wall. Cut access opening in textured wall to expose damaged pipe section, verified leak location, and assessed extent of damage to surrounding wall materials. Repaired compromised copper plumbing line and restored water service to home.
Mason, MI 48854
Completed full air conditioning system replacement at residential property. Removed existing outdoor condenser unit and installed new gray cylindrical AC condenser with horizontal ventilation slats and protective top grille. Unit positioned on existing concrete pad in corner location against beige vinyl siding. Connected electrical disconnect box to new unit via gray conduit, verified proper electrical connections and grounding. Installed white PVC condensate drain line with proper pitch and termination. Confirmed unit placement on elevated concrete pad with adequate clearance for airflow and service access. Landscaping area around unit maintained with mulch bed and decorative stone border featuring stacked gray pavers. Verified all manufacturer specifications, tested system operation, and confirmed proper cooling performance upon startup.
Completed full air conditioning system replacement at residential property. Removed existing outdoor condenser unit and installed new gray cylindrical AC condenser with horizontal ventilation slats and protective top grille. Unit positioned on existing concrete pad in corner location against beige vinyl siding. Connected electrical disconnect box to new unit via gray conduit, verified proper electrical connections and grounding. Installed white PVC condensate drain line with proper pitch and termination. Confirmed unit placement on elevated concrete pad with adequate clearance for airflow and service access. Landscaping area around unit maintained with mulch bed and decorative stone border featuring stacked gray pavers. Verified all manufacturer specifications, tested system operation, and confirmed proper cooling performance upon startup.
Avery M.
Avery M. Checked in
Completed full air conditioning system replacement at residential property. Removed existing outdoor condenser unit and installed new gray cylindrical AC condenser with horizontal ventilation slats and protective top grille. Unit positioned on existing concrete pad in corner location against beige vinyl siding. Connected electrical disconnect box to new unit via gray conduit, verified proper electrical connections and grounding. Installed white PVC condensate drain line with proper pitch and termination. Confirmed unit placement on elevated concrete pad with adequate clearance for airflow and service access. Landscaping area around unit maintained with mulch bed and decorative stone border featuring stacked gray pavers. Verified all manufacturer specifications, tested system operation, and confirmed proper cooling performance upon startup.
Mason, MI 48854
Mason, MI - Completed annual cooling system tune-up and preventative maintenance inspection. System evaluated and found operating within normal parameters; no immediate repairs required at this time.
Brandon E.
Brandon E. Checked in
Completed annual cooling system tune-up and preventative maintenance inspection. System evaluated and found operating within normal parameters; no immediate repairs required at this time.
Mason, MI 48854
Completed annual cooling maintenance on 11-year-old air conditioning system. Performed comprehensive tune-up including inspection of evaporator coil, which showed normal dust accumulation for unit age, and verified proper airflow through supply grilles. All components operating within manufacturer specifications. System tested and confirmed functioning properly. Documentation photos captured for service records.
Completed annual cooling maintenance on 11-year-old air conditioning system. Performed comprehensive tune-up including inspection of evaporator coil, which showed normal dust accumulation for unit age, and verified proper airflow through supply grilles. All components operating within manufacturer specifications. System tested and confirmed functioning properly. Documentation photos captured for service records.
Brandon E.
Brandon E. Checked in
Completed annual cooling maintenance on 11-year-old air conditioning system. Performed comprehensive tune-up including inspection of evaporator coil, which showed normal dust accumulation for unit age, and verified proper airflow through supply grilles. All components operating within manufacturer specifications. System tested and confirmed functioning properly. Documentation photos captured for service records.
Mason, MI 48854
Responded to customer complaint of loud banging noise from outside AC unit upon startup. Inspected exterior condensing unit and traced refrigerant lines into attic space. Found inadequately secured suction line creating vibration and impact noise against floor joists when compressor engaged. Repositioned and properly secured copper refrigerant line and associated flex duct using appropriate mounting straps and clamps to eliminate contact with structural framing members. Cycled system multiple times to verify noise elimination and proper operation.
Responded to customer complaint of loud banging noise from outside AC unit upon startup. Inspected exterior condensing unit and traced refrigerant lines into attic space. Found inadequately secured suction line creating vibration and impact noise against floor joists when compressor engaged. Repositioned and properly secured copper refrigerant line and associated flex duct using appropriate mounting straps and clamps to eliminate contact with structural framing members. Cycled system multiple times to verify noise elimination and proper operation.
Chris J.
Chris J. Checked in
Responded to customer complaint of loud banging noise from outside AC unit upon startup. Inspected exterior condensing unit and traced refrigerant lines into attic space. Found inadequately secured suction line creating vibration and impact noise against floor joists when compressor engaged. Repositioned and properly secured copper refrigerant line and associated flex duct using appropriate mounting straps and clamps to eliminate contact with structural framing members. Cycled system multiple times to verify noise elimination and proper operation.
Mason, MI 48854
Mason, MI - Installed a Bradford White 40-gallon short natural draft water heater in residential utility room. Connected all water supply lines, gas piping, and exhaust venting with proper fittings and secured galvanized duct at top of unit. Verified all connections, tested system operation, and confirmed proper venting and drainage function upon completion.
Jeremiah D.
Jeremiah D. Checked in
Installed a Bradford White 40-gallon short natural draft water heater in residential utility room. Connected all water supply lines, gas piping, and exhaust venting with proper fittings and secured galvanized duct at top of unit. Verified all connections, tested system operation, and confirmed proper venting and drainage function upon completion.
Mason, MI 48854
Mason, MI - Conducted on-site assessment for water heater replacement in residential property with existing unit at 18 years of age, nearing end of typical service life. Evaluated mechanical room configuration, photographed existing installation including HVAC ductwork and copper plumbing connections, and provided comprehensive estimate for new water heater installation in standard residential application.
Lee E.
Lee E. Checked in
Conducted on-site assessment for water heater replacement in residential property with existing unit at 18 years of age, nearing end of typical service life. Evaluated mechanical room configuration, photographed existing installation including HVAC ductwork and copper plumbing connections, and provided comprehensive estimate for new water heater installation in standard residential application.
Mason, MI 48854
Completed comprehensive super tune-up on 4-year-old Rheem air conditioning system. Performed full system inspection including electrical components, capacitor testing, contactor evaluation, and refrigerant line assessment. All components found operating within manufacturer specifications; capacitor showing proper microfarad readings, contactor functioning correctly with clean contacts, and refrigerant lines properly insulated with no visible leaks. Cleaned debris from capacitor mounting platform and verified all wire connections secure. System tested and confirmed cooling efficiently with no issues identified.
Completed comprehensive super tune-up on 4-year-old Rheem air conditioning system. Performed full system inspection including electrical components, capacitor testing, contactor evaluation, and refrigerant line assessment. All components found operating within manufacturer specifications; capacitor showing proper microfarad readings, contactor functioning correctly with clean contacts, and refrigerant lines properly insulated with no visible leaks. Cleaned debris from capacitor mounting platform and verified all wire connections secure. System tested and confirmed cooling efficiently with no issues identified.
Brandon E.
Brandon E. Checked in
Completed comprehensive super tune-up on 4-year-old Rheem air conditioning system. Performed full system inspection including electrical components, capacitor testing, contactor evaluation, and refrigerant line assessment. All components found operating within manufacturer specifications; capacitor showing proper microfarad readings, contactor functioning correctly with clean contacts, and refrigerant lines properly insulated with no visible leaks. Cleaned debris from capacitor mounting platform and verified all wire connections secure. System tested and confirmed cooling efficiently with no issues identified.
Mason, MI 48854
Mason, MI - Responded to cooling deficiency complaint on 14-year-old air conditioning system in standard construction residence. Performed diagnostic inspection using borescope camera to examine evaporator coil condition and heat exchanger fins. Visual inspection revealed coil fin structure and internal component condition. Unit operational but underperforming on cooling capacity as reported.
Chris J.
Chris J. Checked in
Responded to cooling deficiency complaint on 14-year-old air conditioning system in standard construction residence. Performed diagnostic inspection using borescope camera to examine evaporator coil condition and heat exchanger fins. Visual inspection revealed coil fin structure and internal component condition. Unit operational but underperforming on cooling capacity as reported.
Mason, MI 48854
Completed inspector-requested corrections for quoted repair work. Addressed floor opening in kitchen area where hardwood flooring meets stairwell access to basement level, ensuring proper framing and subflooring exposure meets code requirements. Verified and documented foam insulation sealing at basement ceiling/wall junction and confirmed electrical/mechanical component placement on concrete step surface meets inspection standards.
Completed inspector-requested corrections for quoted repair work. Addressed floor opening in kitchen area where hardwood flooring meets stairwell access to basement level, ensuring proper framing and subflooring exposure meets code requirements. Verified and documented foam insulation sealing at basement ceiling/wall junction and confirmed electrical/mechanical component placement on concrete step surface meets inspection standards.
James W.
James W. Checked in
Completed inspector-requested corrections for quoted repair work. Addressed floor opening in kitchen area where hardwood flooring meets stairwell access to basement level, ensuring proper framing and subflooring exposure meets code requirements. Verified and documented foam insulation sealing at basement ceiling/wall junction and confirmed electrical/mechanical component placement on concrete step surface meets inspection standards.
Mason, MI 48854
Mason, MI - Successfully completed installation of two new water heaters in mechanical room. Installed one Lochinvar unit and one Bradford White unit side by side, connecting both to existing copper plumbing system with appropriate valves and fittings. Mounted circulation pump on Bradford White unit and completed all electrical connections with proper conduit. All manufacturer specifications followed, units tested and operational.
Trenton J.
Trenton J. Checked in
Successfully completed installation of two new water heaters in mechanical room. Installed one Lochinvar unit and one Bradford White unit side by side, connecting both to existing copper plumbing system with appropriate valves and fittings. Mounted circulation pump on Bradford White unit and completed all electrical connections with proper conduit. All manufacturer specifications followed, units tested and operational.
Mason, MI 48854
Responded to service call for leaking outdoor water spigot at residential property. Upon inspection, accessed plumbing system through ceiling cavity to locate source of leak at copper pipe connection serving exterior hose bib. Repaired faulty valve connection with oxidized copper piping, replaced worn components, and verified system integrity. Created access opening in wall/ceiling to reach affected plumbing, completed repairs, and confirmed no active leaks present upon completion.
Responded to service call for leaking outdoor water spigot at residential property. Upon inspection, accessed plumbing system through ceiling cavity to locate source of leak at copper pipe connection serving exterior hose bib. Repaired faulty valve connection with oxidized copper piping, replaced worn components, and verified system integrity. Created access opening in wall/ceiling to reach affected plumbing, completed repairs, and confirmed no active leaks present upon completion.
Jason M.
Jason M. Checked in
Responded to service call for leaking outdoor water spigot at residential property. Upon inspection, accessed plumbing system through ceiling cavity to locate source of leak at copper pipe connection serving exterior hose bib. Repaired faulty valve connection with oxidized copper piping, replaced worn components, and verified system integrity. Created access opening in wall/ceiling to reach affected plumbing, completed repairs, and confirmed no active leaks present upon completion.
Mason, MI 48854
Responded to no cooling call on 9-year-old Maytag system with thermostat displaying "lacking Y1 feed" fault. Upon arrival, found both heating and cooling functions inoperative following recent heat exchanger replacement performed by another contractor. Inspected Nest thermostat wiring at wall base and traced connections to furnace control board. Identified missing or improperly terminated Y1 wire connection at control board that was disturbed during previous heat exchanger service. Verified all thermostat wiring terminals including RC, W1, G, C, and Y1 connections. Re-established proper Y1 circuit connection at furnace control board terminal strip, ensuring secure termination. Tested system operation through multiple heating and cooling cycles. Confirmed thermostat fault cleared, air conditioning engaging properly on Y1 call, and furnace responding correctly to heat demand. System restored to full functionality with both heating and cooling operating as designed.
Responded to no cooling call on 9-year-old Maytag system with thermostat displaying "lacking Y1 feed" fault. Upon arrival, found both heating and cooling functions inoperative following recent heat exchanger replacement performed by another contractor. Inspected Nest thermostat wiring at wall base and traced connections to furnace control board. Identified missing or improperly terminated Y1 wire connection at control board that was disturbed during previous heat exchanger service. Verified all thermostat wiring terminals including RC, W1, G, C, and Y1 connections. Re-established proper Y1 circuit connection at furnace control board terminal strip, ensuring secure termination. Tested system operation through multiple heating and cooling cycles. Confirmed thermostat fault cleared, air conditioning engaging properly on Y1 call, and furnace responding correctly to heat demand. System restored to full functionality with both heating and cooling operating as designed.
Jordan K.
Jordan K. Checked in
Responded to no cooling call on 9-year-old Maytag system with thermostat displaying "lacking Y1 feed" fault. Upon arrival, found both heating and cooling functions inoperative following recent heat exchanger replacement performed by another contractor. Inspected Nest thermostat wiring at wall base and traced connections to furnace control board. Identified missing or improperly terminated Y1 wire connection at control board that was disturbed during previous heat exchanger service. Verified all thermostat wiring terminals including RC, W1, G, C, and Y1 connections. Re-established proper Y1 circuit connection at furnace control board terminal strip, ensuring secure termination. Tested system operation through multiple heating and cooling cycles. Confirmed thermostat fault cleared, air conditioning engaging properly on Y1 call, and furnace responding correctly to heat demand. System restored to full functionality with both heating and cooling operating as designed.
Mason, MI 48854
# NC-No Cool Service Completed

Responded to no cooling complaint on 2-year-old EnergiAir system. Upon arrival, performed diagnostic testing using refrigerant manifold gauges and digital multimeter to assess system operation. Inspection revealed electrical control issues requiring attention to wiring connections at the condensing unit. Accessed electrical panel and examined CoreSense control board, contactor assembly, and dual-run capacitor (38/5 MFD). Verified proper wire terminations and electrical connections throughout the control circuit. Tested refrigerant pressures on both high and low sides of the system using professional-grade manifold gauge set with color-coded hoses. System restored to proper cooling operation following diagnostic work and necessary corrections to electrical connections.
# NC-No Cool Service Completed

Responded to no cooling complaint on 2-year-old EnergiAir system. Upon arrival, performed diagnostic testing using refrigerant manifold gauges and digital multimeter to assess system operation. Inspection revealed electrical control issues requiring attention to wiring connections at the condensing unit. Accessed electrical panel and examined CoreSense control board, contactor assembly, and dual-run capacitor (38/5 MFD). Verified proper wire terminations and electrical connections throughout the control circuit. Tested refrigerant pressures on both high and low sides of the system using professional-grade manifold gauge set with color-coded hoses. System restored to proper cooling operation following diagnostic work and necessary corrections to electrical connections.
Chris J.
Chris J. Checked in
# NC-No Cool Service Completed Responded to no cooling complaint on 2-year-old EnergiAir system. Upon arrival, performed diagnostic testing using refrigerant manifold gauges and digital multimeter to assess system operation. Inspection revealed electrical control issues requiring attention to wiring connections at the condensing unit. Accessed electrical panel and examined CoreSense control board, contactor assembly, and dual-run capacitor (38/5 MFD). Verified proper wire terminations and electrical connections throughout the control circuit. Tested refrigerant pressures on both high and low sides of the system using professional-grade manifold gauge set with color-coded hoses. System restored to proper cooling operation following diagnostic work and necessary corrections to electrical connections.
Mason, MI 48854
Mason, MI - Completed annual cooling maintenance on 6-year-old ICP system. Performed comprehensive tune-up including filter inspection, refrigerant level check, electrical connections verification, and condensate pump operation test. Confirmed condensate pump is properly elevated on wooden blocks and draining correctly through PVC discharge line; system operating within manufacturer specifications with no issues found.
Brandon E.
Brandon E. Checked in
Completed annual cooling maintenance on 6-year-old ICP system. Performed comprehensive tune-up including filter inspection, refrigerant level check, electrical connections verification, and condensate pump operation test. Confirmed condensate pump is properly elevated on wooden blocks and draining correctly through PVC discharge line; system operating within manufacturer specifications with no issues found.
Mason, MI 48854

Start Saving Today With

Membership Perks

Start Saving Today With

Membership Perks

What To Expect

Discover The Vredevoogd Difference

24/7 Emergency HVAC Service

HVAC emergencies can happen on nights, weekends, and holidays, so our phones are always open to take calls!

100% Satisfaction Guarantee

The Vredevoogd team is dedicated to a promise of 100% client satisfaction with every service we perform.

Background-Checked Technicians

Our employees are background-checked, ensuring you have peace of mind when they enter your home.

Free Estimates

You can expect free, honest, and accurate estimates on replacements and financing options to make fully informed HVAC or plumbing decisions for your home.

Financing Available

We offer various financing options to make our services affordable and accessible for Michigan homeowners.

A+ on BBB

With an A+ BBB rating, Vredevoogd continues to build trust between our company and customers.

24/7 Emergency HVAC Service

HVAC emergencies can happen on nights, weekends, and holidays, so our phones are always open to take calls!

100% Satisfaction Guarantee

The Vredevoogd team is dedicated to a promise of 100% client satisfaction with every service we perform.

Background-Checked Technicians

Our employees are background-checked, ensuring you have peace of mind when they enter your home.

Free Estimates

You can expect free, honest, and accurate estimates on replacements and financing options to make fully informed HVAC or plumbing decisions for your home.

Financing Available

We offer various financing options to make our services affordable and accessible for Michigan homeowners.

A+ on BBB

With an A+ BBB rating, Vredevoogd continues to build trust between our company and customers.

Our Reviews

See What Your Neighbors Are Saying.

Completely professional. Did an outstanding job meeting our needs and time frame. Didn't try to push us to get more than we needed or could afford but made sure we had the right fit for our home.

Amanda S.

Portage, MI

Amanda S.

Portage, MI

Very impressed with Vredevoogd Heating and Cooling. I met three of their techs and all of them were wonderful. We had the air conditioning and furnace installed in one day and they had our house cooled and ready to go by 1pm. Very polite, hard working and honest. Would highly recommend.

Emilee S.

Comstock Park, MI

Emilee S.

Comstock Park, MI

We were having issues with low hot water pressure on/off for a year; lots of sediment in tank. Hot water tank and furnace 20 years old. Asked technician to take a look at the furnace to see if there were any problems and he showed me several failures including large cracks. He told me all the…

Rebecca E.

Holland, MI

Rebecca E.

Holland, MI

I had David G’s help this afternoon locating a leak source, and going over regular maintenance required for my home (I’m an inexperienced first-time owner). I cannot thank him enough for his courteous help, thoughtful advice & time. I look forward to using Vredevoogd’s services in the future!.

Jane O.

Kalamazoo, MI

Jane O.

Kalamazoo, MI

Ryen was PHENOMENAL!!! He explained thoroughly the functioning of my system. He also saved me tons of money in repair along with replacement. Hands down they have truly earned my business!!!! I couldn’t be happier with my visit.

Karenia R.

Lansing, MI

Karenia R.

Lansing, MI