After a day exploring the majestic Fort Custer Recreational Area, comprised of 3,033 acres of lakes and the Kalamazoo River, in Battle Creek, MI, the comforts of home in the heart of Calhoun County await you. To ensure your home is your castle, count on family-owned and -operated Vredevoogd for all your HVAC, plumbing, and generator needs.
With over 60 years of experience, warm summers and winters with multiple days of freezing temperatures are no surprise to Vredevoogd. Our experienced, licensed technicians are ready to provide same-day, 24/7 emergency services to restore your peace of mind.
Don’t wait until something drastic happens — contact the Vredevoogd team today for your home maintenance needs.
24/7 Emergency HVAC Services
There’s never a dull moment with Battle Creek weather. The wear and tear this takes on your home HVAC system means having reliable maintenance services in your back pocket. At Vredevoogd, we’re your one-stop 24/7 emergency shop for:
Heating Services
Don’t let the cold winter winds of Battle Creek sneak up on you — schedule your furnace maintenance before the rush. Our highly trained, trustworthy technicians clean and lubricate your heating system while quickly diagnosing needed heating repairs. If replacement and installation are the next steps, we take the mystery out of choosing the suitable gas or electric furnace, offering a price you can afford.
Air Conditioning Services
No matter the AC brand, our background-checked technicians provide routine AC maintenance to protect the life of your air conditioner, repair coils or cracked hoses for optimal energy efficiency, and, when it’s time to upgrade your cooling system, we’ll provide the best installation and replacement solutions. Ask us about the benefits of a ductless mini-split to keep every room in your home at the perfect temperature.
Air Quality Services
Trust our team to install advanced HVAC filtration technology to combat the spread of allergies, asthma, mold, viruses, and bacteria. In our most brutal winter months, our top-of-the-line Aprilaire humidifiers will help you avoid stagnant, dry, and allergen-filled air.
Join Our Comfort Club Today
With routine preventative maintenance, your HVAC system lasts longer and saves money. That’s why Vredevoogd offers our Comfort Club membership. Join today for biannual tune-ups, discounted service repairs, priority appointment scheduling, and much more!
Quality Plumbing Services
Vredevoogd’s insured, customer-focused professionals will explain every step of the repair, maintenance, or installation process, including replacing and updating pipes and fixtures, installing water heaters, cleaning drain and sewer lines, and ensuring your home is flood-free with superior sump pump servicing.
Professional Generator Services
As a community partner in Battle Creek, we know the challenges an ever-changing climate throws at us during months of volatile weather. Having a generator in top-notch shape provides unprecedented peace of mind for your health and the safety of your home. At Vredevoogd, we offer generator repair, ensuring you won’t be caught with a generator that doesn’t start.
Choose Vredevoogd for HVAC, Plumbing & Generator Services in Battle Creek
Our certified technicians have served Battle Creek and Western Michigan for decades and provide reliable, friendly, customer-centered solutions. Whether you’re ready to update your historic home with new plumbing fixtures or preparing for another wild West Michigan winter with the peace of mind a generator can bring, we look forward to providing innovative, 100% guaranteed service.
For fast, affordable service that’s catered to your home maintenance needs, book your appointment with Vredevoogd today.
Recent Jobs and Reviews in Battle Creek, MI
Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and appreciation. Customers consistently express gratitude for the professionalism, efficiency, and knowledge demonstrated by the service team. Recurring themes include technicians being described as friendly, polite, and courteous, creating a welcoming and comfortable service experience. Many reviewers emphasize the thoroughness of the work performed, with technicians taking time to explain issues clearly, provide detailed assessments, and ensure customers understand the repairs or maintenance being conducted. The communication skills of the team stand out prominently, with customers appreciating transparent explanations and demonstrations of completed work. Efficiency and promptness are frequently highlighted, with customers noting quick problem identification and timely completion of jobs. The professionalism of the service providers is a dominant positive trend, with reviewers consistently praising the knowledgeable approach and respectful demeanor of technicians. Several customers express strong loyalty and intent to continue using the service, with some specifically noting superior diagnostic capabilities compared to competitors. The tone throughout is one of trust, satisfaction, and genuine appreciation for quality workmanship and excellent customer service. Overall, these reviews paint a picture of a highly competent, customer-focused team that consistently delivers reliable and professional HVAC and plumbing services.
Job Locations and Reviews
Responded to no cooling complaint on units 1 and 3 of a three-unit system. Upon inspection, found deteriorated refrigerant line insulation with significant cracking and splitting on affected units, which was contributing to reduced cooling efficiency and inability to satisfy thermostat settings. Documented equipment condition showing aged foam insulation on copper refrigerant lines requiring replacement to restore proper system performance and prevent continued temperature climb throughout the day.
Responded to service call for AO Smith electric water heater not producing hot water. Upon inspection, discovered severe corrosion and rust damage to electrical connections at the upper terminal block. The deterioration was extensive, with heavy oxidation compromising wire connections and creating potential safety hazards. Documented conditions with photographs showing corroded terminals, rust staining, and moisture damage to electrical components. Advised customer of findings and recommended water heater replacement due to the severity of electrical system failure and associated safety concerns.
Successfully completed a comprehensive HVAC system replacement involving the installation of three furnace and air conditioning units at a residential property. All outdoor condenser units were positioned on concrete pads against the brick exterior with proper clearances for airflow and maintenance access. The installations included complete electrical connections, refrigerant line sets, condensate drainage routing, and startup procedures to verify proper system operation and performance specifications.
# CP-Cooling Problem Return visit to diagnose system running constantly when thermostat in off position with fan set to auto mode. Inspected EnergiAir WT 08-2031 unit wiring and control circuits. Examined transformer/relay assembly and verified proper terminal connections at equipment. Checked ecobee thermostat wiring configuration including R, C, W1, W2, G, Y1, Y2, and OB terminals to ensure correct connections and eliminate potential wiring faults causing continuous operation. Documented equipment condition and wiring setup with photographs for diagnostic reference and future service needs.
Installed Corro-Protec powered anode rod system on existing water heater to prevent tank corrosion and extend equipment lifespan. Connected powered anode to dedicated electrical outlet, verified proper operation, and documented installation with updated labeling on tank.
Completed annual cooling maintenance on EnergiAir system including inspection of condensate pump assembly, verification of drain line operation, and photographic documentation of equipment condition. All mechanical components inspected and found operational with normal wear patterns observed on mounting surfaces and utility area equipment.
Responded to service call for cooling system running constantly when thermostat was in the off position. Upon arrival, confirmed thermostat was set to AUTO mode rather than ON, which was causing continuous system operation. Inspected HVAC unit interior components including electrical connections, wire terminations with wire nuts, control relay switches, and motor assembly to verify proper operation and rule out any control circuit failures. Checked electrical wiring configuration and confirmed all connections were secure. Educated customer on proper thermostat operation and the difference between AUTO and ON fan settings to prevent future confusion and unnecessary system runtime.
Completed annual cooling system maintenance and inspection as part of 2-year EnergiAir warranty program. Performed comprehensive AC tune-up including visual inspection of outdoor condenser unit, verified proper fin alignment and spacing on heat exchanger coils, and assessed overall system cleanliness. Condenser coils showed minor dust accumulation and slight debris presence but remained in functional condition with no significant blockages affecting airflow. All components inspected and documented with photos showing satisfactory operational status for continued seasonal use.
Successfully installed a 20KW Kohler standby generator with 200A service upgrade at residential property. Coordinated utility disconnect and reconnect services, completed electrical service upgrade with new meter installation, and ran conduit from main service panel to generator unit mounted on exterior brick wall. All work performed under electrical permit with final inspection and gas pressure test completed and approved.
Completed full air conditioning system replacement including outdoor condensing unit and indoor components. Installed new AC unit on concrete pad with proper refrigerant line connections and condensate drainage via white PVC piping routed along exterior siding. Verified all ductwork connections to existing furnace system in basement, ensured proper electrical connections at panel, and tested system operation for optimal cooling performance.
Responded to complaint of rotten egg smell from 3-year-old Bradford White water heater. Inspected unit and plumbing connections, identifying hydrogen sulfide odor typically caused by sulfate-reducing bacteria reacting with magnesium anode rod. Recommended anode rod replacement with aluminum/zinc alloy rod or installation of powered anode to eliminate odor while maintaining tank corrosion protection.
Completed annual cooling maintenance on residential split system air conditioning unit. Addressed customer concern regarding noise during startup operation. Performed comprehensive system inspection including outdoor condenser unit and indoor air handler. Checked refrigerant levels, electrical connections, and capacitor operation. Inspected condenser fan motor and blade assembly for proper operation and unusual wear patterns. Verified adequate airflow through condenser coils and cleared debris from unit perimeter. Tested system startup sequence and monitored for abnormal sounds. Evaluated compressor operation and amp draw. Inspected condensate drain line for proper flow. Checked thermostat calibration and system cycling. System operating within normal parameters following tune-up. Recommended monitoring unit for any recurring startup noise and advised customer to contact for service if issue persists.
Responded to gas leak call where strong gas odor was detected when furnace gas valve was turned on. Upon inspection, identified gas leak at furnace gas valve connection that occurred following recent AC installation work in the vicinity. Tightened gas valve connection, performed leak test with soap solution to verify repair, and confirmed no further gas odor present when valve reopened.
Completed annual cooling maintenance inspection on residential HVAC system. Performed comprehensive system evaluation including inspection of Denkida control module, verified all electrical connections and wiring harnesses secure and properly terminated. Documented equipment condition with photos showing control board installation, multi-conductor wiring, and system components. All safety controls tested and operating within normal parameters, system ready for cooling season operation.
Completed annual cooling maintenance inspection on 15-year-old AC system. Performed standard preventive maintenance procedures, documented equipment condition with photos showing outdoor unit installation, refrigerant line penetration through building exterior, and utility connections. All systems operational with no immediate service needs identified at time of visit.
Completed comprehensive ASTU-AC Super Tune-up on 15-year-old air conditioning system, including thorough cleaning of evaporator coils which showed moderate dust and debris accumulation on fin surfaces. Performed full system diagnostics with calibrated digital instrumentation, verified refrigerant temperatures and pressures, inspected condensate drain lines for proper operation, and confirmed all electrical connections and safety controls were functioning within manufacturer specifications.
Completed annual cooling maintenance on 10-year-old Trane air conditioning system. Performed comprehensive tune-up including system inspection, temperature diagnostics showing supply air at 68.4°F, and verified proper operation of condensate pump drainage system with all discharge lines flowing correctly.
Responded to no cooling complaint on a 4-year-old air conditioning system. Upon arrival, performed diagnostic inspection of outdoor unit and electrical connections. Inspected terminal block connections and wiring at the unit, documenting the condition of all wire terminations including power and control wiring. Photographed electrical components for service records showing multiple wire connections to terminal strips with various colored conductors in active use on outdoor equipment.
Completed kitchen drain rebuild involving replacement of deteriorated PVC drain piping in crawlspace area beneath kitchen. Installed new white PVC drain line with 90-degree elbow fittings to restore proper drainage flow, working around existing copper water supply lines and aged floor joists. Vertical drain stack connection completed where pipe transitions through floor structure to tie into existing plumbing system.
Responded to generator battery charging alert. Technician inspected electrical connections and control panel wiring to diagnose charging system failure. Examined terminal blocks, wire connections, and control module components. Documented existing conditions with photos showing terminal block assembly with multiple colored wire connections and control panel interior containing electrical module with fuse protection and various circuit connections. Investigation revealed potential issues with battery charging circuit requiring further evaluation upon return visit.