When you need superior HVAC and plumbing services in Grand Rapids, trust the team at Vredevoogd. With over 60 years in the industry, our team of licensed, insured, and background-checked technicians is here to provide outstanding work and exceptional customer service. At Vredevoogd, our goal is to give our customers peace of mind, and with our 24/7 emergency HVAC services and free estimates on replacements, we promise to be there for you when you need us most!
For all your HVAC and plumbing needs in Grand Rapids, call Vredevoogd today or contact us online!

Professional HVAC Services in Grand Rapids, MI
With the inconsistent weather in Michigan, homeowners rely on both their heating and cooling all year to stay comfortable in their homes. With our comprehensive HVAC services, you can ensure that your home comfort system is operating at peak performance so that your home is always at the perfect temperature.
Air Conditioning Services in grand Rapids, MI
When temperatures rise in the Midwest, you may need high-quality services for your cooling system. At Vredevoogd, our expert technicians offer various cooling services, including installation, replacement, repair, and maintenance for your central air and ductless mini-splits, to ensure they are efficient and effective all summer.
Heating Services in grand Rapids, MI
Your gas furnace keeps you warm and cozy during the frigid nights of Michigan winters. With our comprehensive heating services from our highly qualified professionals, we’ll provide you with unmatched installation, replacement, repair, and maintenance to ensure top-notch performance from your furnace.
Air Quality Services in Grand Rapids
With more and more time spent indoors, ensuring that your indoor air is safe and clean is even more critical. That’s why our team offers various air quality services like Micro Powerguard air filters, UVC air quality control, and humidifiers to improve the air you and your family breathe daily. With these services, you’ll experience great benefits like reduced asthma and allergy symptoms, improved HVAC performance, and a fresher smell throughout your home.
Call Vredevoogd today to discuss how our air quality services can improve your home and health.
Reliable Plumbing Services in Grand Rapids, MI
The expert plumbers at Vredevoogd work hard to help you maintain a reliable and functional plumbing system in your Grand Rapids home. Our comprehensive plumbing services include installation, repair, and maintenance of your home’s general plumbing, as well as specialized services like water heater service, sump pump services, and drain cleaning.
From dripping faucets to broken water heaters, our plumbers handle it all! Call today to schedule your plumbing service in Grand Rapids!
Top-Rated Generator Services
Don’t get stuck in a storm or heat wave without power! You and your family can stay safe and comfortable during any power outage by installing a whole-home generator. With a continuous power supply from a generator, you can help protect your home and property while ensuring comfort and convenience. With our generator services, including installation, replacement, and repair, we guarantee your system is always prepared to keep your home running smoothly.
Call Vredevoogd today to schedule your generator services in Grand Rapids or contact us online!
Why Choose Vredevoogd in Grand Rapids?
At Vredevoogd, we’re here when you need us most. From HVAC to plumbing, our same-day services ensure you get the help you need to keep your home and family comfortable. Since 1964, we’ve prioritized stress-free service for our customers in Grand Rapids, Michigan. With our financing options and military and veteran discounts, you will get high-quality service without breaking the bank.
Trust Vredevoogd for superior HVAC and plumbing services and more! Call us today or contact us online!
Recent Jobs and Reviews in Grand Rapids, MI
Customers say: # Customer Sentiment Analysis The reviews reflect an overwhelmingly positive sentiment toward the service provided. Customers consistently express high satisfaction with the professionalism, friendliness, and efficiency of the technicians. A recurring theme is appreciation for clear communication, with many customers highlighting how thoroughly technicians explained technical issues, procedures, and solutions. The service personnel are frequently described as knowledgeable, respectful, and helpful. Timeliness appears to be another strength, with several mentions of punctuality and quick completion of work. Customers value the transparency regarding costs and potential issues, noting that even when upselling occurred, it was done without pressure. The quality of workmanship receives significant praise, with terms like "thorough," "neat," and "excellent" appearing throughout. Many reviews indicate strong customer loyalty, with explicit statements about willingness to recommend the service to others or use it again themselves. The overall tone is decidedly positive, reflecting a customer base that feels well-served and respected.
Job Locations and Reviews
Completed full installation of new furnace and water heater in basement utility area. Installed furnace with metallic flex ductwork connections to existing duct system, ensuring proper airflow and secure mounting. Installed new water heater with appropriate plumbing connections, shut-off valve, and safety components. Both units tested and verified operational upon completion.
Completed comprehensive plumbing inspection and assessment of bathroom fixtures in preparation for scheduled full home repairs. Documented existing conditions of bathtub/shower area with yellow tile surround, chrome fixtures, and vanity area with beige tile countertop and undermount sink to establish baseline for upcoming five-hour repair service.
Completed full water heater replacement installation in residential utility space. Removed existing unit and installed new automatic storage water heater with proper venting system, including metal exhaust vent pipe routed from top of unit. Connected all copper supply lines, installed PEX flexible tubing connections, and mounted shut-off valves with blue handles on dedicated panel board for easy access and system control. Verified all plumbing connections for proper seal and tested unit operation to ensure safe and efficient functionality. Installation completed per manufacturer specifications with all required safety labels and compliance markings in place.
Completed annual heating maintenance on 11-year-old Heil furnace system. Performed comprehensive tune-up including visual inspection of heat exchanger and internal components using borescope camera, which revealed normal operational wear patterns with some surface oxidation present on metallic surfaces. All system components inspected and serviced as part of routine preventative maintenance program.
Completed annual heating maintenance on EnergiAir furnace system in basement location. Performed comprehensive tune-up including filter inspection, burner assembly cleaning, heat exchanger examination, blower motor lubrication, and safety control testing. System operational with no humidifier present. All components functioning within manufacturer specifications. Documented equipment condition with photographs. Warranty valid through January 2035.
Completed comprehensive furnace and air conditioning tune-up on two 4-year-old HVAC units. Performed thorough inspection of internal components including refrigerant lines, electrical connections, and control systems. Verified proper operation of disconnect box, checked all wire connections and terminals for security, and confirmed system functionality. All equipment tested and operating within manufacturer specifications.
Completed annual heating maintenance on 10-year-old Goodman furnace system with coil manufactured in 2022. Performed comprehensive tune-up including inspection of all major components, burner assembly cleaning, and filter replacement. Unit operates without humidifier. All systems tested and confirmed operational within manufacturer specifications.
Completed annual heating maintenance on three furnace systems and three Aprilaire humidifiers. Performed comprehensive tune-up procedures including filter inspection, burner assembly cleaning, heat exchanger examination, blower motor lubrication, and combustion analysis on all units. Verified proper operation of safety controls, limit switches, and flame sensors. Inspected and serviced all three humidifiers, checking water supply lines, drainage systems, evaporator pads, and humidistat calibration. Confirmed proper airflow and humidity distribution throughout the systems. All equipment tested and left in proper working condition with warranty coverage noted through October 2033.
Performed no-charge assessment of residential HVAC system consisting of two outdoor condensing units installed in side yard landscaped area. Documented equipment placement, drainage configuration, and site conditions with photographs for customer records and future service reference.
Responded to heating system failure on 12-year-old Luxaire furnace with intermittent ignition and inadequate temperature maintenance. Upon inspection, discovered significant condensation accumulation on pressure switch tubing, indicating drainage obstruction affecting proper system operation. Performed diagnostic testing of electrical components and flame sensor circuit to identify ignition inconsistencies. Cleared condensate drain line blockage, cleaned flame sensor, and verified proper pressure switch operation. System tested successfully with consistent ignition sequence and proper heating cycle restored to maintain desired temperature setpoint.
Completed annual heating and cooling maintenance on Carrier furnace, air conditioning system, and humidifier per 3-year service agreement. Performed comprehensive tune-up including inspection of all HVAC components, cleaned and tested fan assembly, verified proper operation of condensate drainage system and PVC piping, checked electrical connections and wiring, and documented equipment condition with photos showing all systems in normal operating condition.
Completed installation of a 40-gallon natural gas water heater in basement utility area. Unit was properly positioned, vented with metallic ductwork, and connected to existing copper plumbing lines with all gas and water connections secured according to manufacturer specifications and local code requirements.
# Boiler Zone Valve Repair Responded to service call for 28-year-old Utica boiler with heating zones not functioning properly. Upon arrival, confirmed that one of four zone valves was unresponsive to thermostat calls, resulting in inadequate heat distribution to affected areas while other zones operated normally. Conducted systematic diagnosis of the boiler's multi-zone heating system. Inspected zone valve assembly and associated wiring at the manifold. Located problematic zone valve controlling basement heating area. Tested electrical connections and confirmed zone valve motor failure preventing valve actuator from opening when thermostat called for heat. Examined the zone valve control board and relay system mounted in the joist space above the piping. Verified proper voltage supply to the malfunctioning zone. Determined the brass-bodied zone valve with yellow actuator motor had seized internally and required replacement. Isolated the affected heating zone using existing shut-off
# Plumbing Project Install - Tub/Shower with Surround Completed full installation of tub/shower combination unit with integrated wall surround system. Removed existing bathing fixtures and prepared rough-in plumbing connections for new installation. Set and leveled acrylic bathtub unit, ensuring proper drain alignment and secure anchoring to wall studs. Installed three-piece shower surround wall panels with integrated corner shelving units, sealing all seams and joints with waterproof adhesive and caulking to prevent moisture intrusion. Mounted chrome shower valve trim kit and coordinating showerhead assembly to wall panels per manufacturer specifications. Connected supply lines to mixing valve and verified proper hot/cold water operation and temperature control. Performed final pressure testing of all connections to confirm leak-free installation. Completed finish caulking around tub perimeter and wall panel seams. Cleaned work area and removed all debris and packaging materials. S
# Tankless Water Heater Repair Completion Service technician returned from lunch break to complete repairs on tankless water heater unit. Internal components were accessed and serviced, including inspection and work on gas valve assembly, burner components, heat exchanger connections, and associated plumbing lines. Electrical connections and power supply to unit were verified, with proper grounding and outlet configuration confirmed. Copper supply lines with isolation valves and drain pan assembly were inspected and confirmed operational. All mechanical linkages, flexible gas connections, and safety components were tested and verified functioning properly before completing service and restoring unit to normal operation.
# Service Report: No Heat Call Responded to no heat call where Sensi touch thermostat displayed blank screen with no power. Upon arrival, inspected HVAC system and thermostat wiring. Identified failed thermostat due to loss of power from system. Verified furnace operation and confirmed heating system was functional but unable to receive commands from inoperative thermostat. Restored heat to residence by addressing thermostat power issue and confirming proper system communication and operation.
# Service Report: No Heat Call Responded to no heat service call for 12-year-old carrier furnace reported to be blowing cold air. Upon arrival, found customer utilizing multiple portable electric space heaters throughout residence due to lack of central heating. Conducted diagnostic inspection of heating system including visual examination of furnace components and ductwork. Observed evidence of potential condensate or moisture issues on supply ductwork as indicated by rust-colored staining on insulated piping. System age and condition suggest underlying mechanical or ignition failure preventing proper heat delivery. Documented equipment condition and temporary heating measures in place with photographic evidence for service records.
# Annual Heating Visit Summary Completed comprehensive annual heating maintenance on 4-year-old Carrier furnace model WT 11-2031 with integrated humidification system. Performed standard tune-up procedures including visual inspection of all accessible components, burner assembly evaluation, and heat exchanger examination. Inspected humidifier operation and mounting hardware, verifying proper integration with HVAC system. Evaluated ductwork connections and cabinet integrity, noting normal wear consistent with system age. Documented equipment condition through photographic records showing humidifier valve assembly, control components, and cabinet interior. All system components found operational with no immediate service needs identified. Equipment remains under coverage through 2025. Customer contact information verified and updated in service records.
# Service Report: Water Heater Replacement Estimate Completed on-site assessment for water heater replacement in residential utility space. Existing Bradford White water heater unit is positioned in confined area with limited clearance, located behind furnace equipment requiring partial HVAC system disassembly for proper access. Documented current installation including copper supply line connections, brass shut-off valves, galvanized flue vent system, and expansion tank mounting. Evaluated spatial constraints and confirmed furnace will need to be temporarily relocated to facilitate safe removal of old unit and installation of replacement water heater. Customer requested expedited replacement service due to immediate need.
# Annual Heating Service Visit Summary Completed scheduled annual heating system maintenance and furnace tune-up service. Performed comprehensive inspection of HVAC system components including ductwork examination and heating equipment evaluation. Documented system conditions through photographic records showing interior ductwork with normal dust accumulation on reflective insulation surfaces and heating appliance plumbing connections with brass fittings and shut-off valves in serviceable condition. System operational with no humidifier service required per customer specifications.