Top HVAC & Plumbing Service & Repair in West Olive, MI
24/7 Emergency Service
HVAC emergencies happen when you least expect them. Contact the professionals at Vredevoogd to take care of the job if you’re dealing with a heating or cooling emergency. We have the necessary skills and tools to fix your system so you can safely use it once again. Call the team at 844-482-2365 to get emergency HVAC services in Michigan.

HVAC, Plumbing & Generator Services in West Olive, MI

West Olive, MI, residents know a reliable home comfort system is essential for year-round comfort and well-being. That’s where Vredevoogd comes in. We offer comprehensive HVAC and plumbing services to meet the needs of West Olive homeowners.

With over 60 years of experience and a commitment to quality and efficiency, we are your trusted partner for all things heating, cooling, and plumbing.

Keep your home running smoothly with HVAC, plumbing, or generator services from Vredevoogd. Call 844-482-2365 to book your consultation in West Olive today.

Vredevoogd technician speaking to a homeowner during a service appointment

24/7 Emergency HVAC Services

Unexpected heating and cooling emergencies can occur at any time, and that’s why Vredevoogd provides 24/7 emergency HVAC services in West Olive. Our team is always ready to deliver immediate, reliable solutions for those who need us.

We’ll help restore your comfort quickly. Whether it’s a sweltering summer day or a freezing winter night, you can count on us to be there when you need us most.

Heating Services

The chill of Michigan winters is no match for our heating services. From modern gas furnaces to comprehensive system maintenance, we ensure your home remains warm and inviting.

Our technicians are well-versed in all heating systems and are ready to install, replace, or repair as needed to keep your family cozy.

Cooling Services

Our cooling services are your go-to solution when West Olive’s summer heat intensifies. We offer expert installation, timely replacement, prompt repairs, and regular maintenance to ensure comfort.

Ductless mini-splits are one of our specialties, providing efficient cooling without extensive ductwork.

Air Quality Services

Good air quality is essential for your family’s health and comfort. We enhance your home’s air with top-notch humidifiers, ensuring that the air you breathe is not only warm or cool enough but also clean and balanced.

Exceptional Plumbing Services

Plumbing problems can be a significant inconvenience. Our plumbing services are designed to address issues efficiently and effectively. Our team of friendly and skilled professionals can help you with plumbing installation, repairs, and maintenance.

We have the expertise to handle everything, from water heaters to sump pumps and drain cleaning to sewer services. Trust us to keep your plumbing system flowing smoothly.

Count on our top-tier plumbing services for your West Olive home. Call Vredevoogd at 844-482-2365 to book your plumbing appointment today.

Professional Generator Services

Our generator services ensure your home remains powered, even when the grid does not. We deliver comprehensive generator services, including generator repairs in West Olive.

With Vredevoogd, you can trust you’ll be ready, no matter what Mother Nature brings. Our installation and repair services are top-notch, providing a reliable backup power source whenever needed.

For expert generator services in West Olive, choose Vredevoogd. Schedule your appointment at 844-482-2365.

Why Choose Vredevoogd in West Olive?

Choosing Vredevoogd is choosing a company that understands the needs of West Olive’s residents. Our licensed, insured, and background-checked technicians are ready to provide 24/7 emergency services, with same-day service options available.

We value our veterans, military members, and seniors, offering them special discounts. With free estimates on replacements and flexible financing options, we ensure quality service without financial stress. Vredevoogd is the name West Olive residents have turned to for over half a century for service that defines dependability and expertise.

Schedule your HVAC, plumbing, or generator services in West Olive by calling 844-482-2365 today.

Recent Jobs and Reviews in West Olive, MI

Job Locations and Reviews

West Olive, MI - Completed comprehensive AC tune-up on two 17-year-old Energy brand units. Discovered heavily corroded contactor with significant rust and oxidation buildup requiring immediate attention, along with substantial dirt and debris accumulation throughout electrical compartment. Performed thorough system inspection, cleaned components, verified all electrical connections, tested capacitor functionality, and documented equipment condition with photos for customer records.
Nick W.
Nick W. Checked in
Completed comprehensive AC tune-up on two 17-year-old Energy brand units. Discovered heavily corroded contactor with significant rust and oxidation buildup requiring immediate attention, along with substantial dirt and debris accumulation throughout electrical compartment. Performed thorough system inspection, cleaned components, verified all electrical connections, tested capacitor functionality, and documented equipment condition with photos for customer records.
West Olive, MI 49460
Completed annual cooling maintenance on 11-year-old EnergiAir system. Inspected electrical contactor and control circuit connections, noting normal wear and dust accumulation on components. Checked condensate drain pan for proper operation and drainage. All electrical connections secure with appropriate wire routing. System operational and ready for cooling season.
Completed annual cooling maintenance on 11-year-old EnergiAir system. Inspected electrical contactor and control circuit connections, noting normal wear and dust accumulation on components. Checked condensate drain pan for proper operation and drainage. All electrical connections secure with appropriate wire routing. System operational and ready for cooling season.
Matt H.
Matt H. Checked in
Completed annual cooling maintenance on 11-year-old EnergiAir system. Inspected electrical contactor and control circuit connections, noting normal wear and dust accumulation on components. Checked condensate drain pan for proper operation and drainage. All electrical connections secure with appropriate wire routing. System operational and ready for cooling season.
West Olive, MI 49460
Provided estimate for complete air conditioning system installation at property with existing Ameristar natural gas furnace and condensate pump but no cooling capability. Quote includes wall-bracket mounted condensing unit, cased evaporator coil, refrigerant line set, and coil condensate drain line with proper routing to existing pump. Homeowner possesses HVAC/R experience and may assist with installation to reduce labor costs.
Provided estimate for complete air conditioning system installation at property with existing Ameristar natural gas furnace and condensate pump but no cooling capability. Quote includes wall-bracket mounted condensing unit, cased evaporator coil, refrigerant line set, and coil condensate drain line with proper routing to existing pump. Homeowner possesses HVAC/R experience and may assist with installation to reduce labor costs.
Mike V.
Mike V. Checked in
Provided estimate for complete air conditioning system installation at property with existing Ameristar natural gas furnace and condensate pump but no cooling capability. Quote includes wall-bracket mounted condensing unit, cased evaporator coil, refrigerant line set, and coil condensate drain line with proper routing to existing pump. Homeowner possesses HVAC/R experience and may assist with installation to reduce labor costs.
West Olive, MI 49460
West Olive, MI - Completed annual cooling maintenance and tune-up on 12-year-old Payne air conditioning system with condenser model year 2023. Performed comprehensive inspection of outdoor unit, checked refrigerant levels, cleaned condenser coils, verified electrical connections, tested capacitor and contactor operation, and confirmed proper system operation and airflow.
Mitch H.
Mitch H. Checked in
Completed annual cooling maintenance and tune-up on 12-year-old Payne air conditioning system with condenser model year 2023. Performed comprehensive inspection of outdoor unit, checked refrigerant levels, cleaned condenser coils, verified electrical connections, tested capacitor and contactor operation, and confirmed proper system operation and airflow.
West Olive, MI 49460
Completed annual cooling system tune-up and preventative maintenance inspection. Verified proper operation of condensate pump with associated PVC drainage lines, inspected HVAC equipment including furnace/air handler unit, and documented system conditions with photographs. All equipment found operating within normal parameters under current warranty coverage extending through July 2034.
Completed annual cooling system tune-up and preventative maintenance inspection. Verified proper operation of condensate pump with associated PVC drainage lines, inspected HVAC equipment including furnace/air handler unit, and documented system conditions with photographs. All equipment found operating within normal parameters under current warranty coverage extending through July 2034.
Shane M.
Shane M. Checked in
Completed annual cooling system tune-up and preventative maintenance inspection. Verified proper operation of condensate pump with associated PVC drainage lines, inspected HVAC equipment including furnace/air handler unit, and documented system conditions with photographs. All equipment found operating within normal parameters under current warranty coverage extending through July 2034.
West Olive, MI 49460
Responded to intermittent hot water outage concerns on a 1-year-old Bradford White water heater. Inspected unit operation, verified proper function of all components, and confirmed adequate hot water production. Temperature setting was adjusted upward by 10 degrees per customer request to address availability issues. Unit operating within normal parameters at time of inspection with no immediate deficiencies noted.
Responded to intermittent hot water outage concerns on a 1-year-old Bradford White water heater. Inspected unit operation, verified proper function of all components, and confirmed adequate hot water production. Temperature setting was adjusted upward by 10 degrees per customer request to address availability issues. Unit operating within normal parameters at time of inspection with no immediate deficiencies noted.
Gavin W.
Gavin W. Checked in
Responded to intermittent hot water outage concerns on a 1-year-old Bradford White water heater. Inspected unit operation, verified proper function of all components, and confirmed adequate hot water production. Temperature setting was adjusted upward by 10 degrees per customer request to address availability issues. Unit operating within normal parameters at time of inspection with no immediate deficiencies noted.
West Olive, MI 49460
West Olive, MI - Responded to noise complaint on newly installed EnergiAir AC unit. Upon inspection, unit was operating and cooling properly. Inspected outdoor condenser unit and electrical connections, including contactor assembly with visible copper coil and multiple circuit wiring. Verified all electrical connections were secure and properly terminated. Identified noise source as normal operational sounds from new contactor during compressor cycling. Explained to customer that these sounds are typical for new equipment and should diminish as components settle during break-in period. Unit left in proper working condition with no mechanical deficiencies found.
Ryan E.
Ryan E. Checked in
Responded to noise complaint on newly installed EnergiAir AC unit. Upon inspection, unit was operating and cooling properly. Inspected outdoor condenser unit and electrical connections, including contactor assembly with visible copper coil and multiple circuit wiring. Verified all electrical connections were secure and properly terminated. Identified noise source as normal operational sounds from new contactor during compressor cycling. Explained to customer that these sounds are typical for new equipment and should diminish as components settle during break-in period. Unit left in proper working condition with no mechanical deficiencies found.
West Olive, MI 49460
Responded to no cooling call on 20-year-old Comfortmaker R22 system with history of rodent damage from previous season that had caused grounded 24V wiring and corroded dual capacitor and contactor. Upon arrival, accessed condenser unit and documented extensive interior corrosion and rust throughout cabinet from prolonged moisture exposure. Inspected electrical connections and wiring harness at contactor and terminal block, noting deteriorated condition of components. Photographed damaged areas showing rust accumulation at base of unit and around connection points, as well as exterior disconnect and utility boxes. Homeowner authorized remotely via phone after reviewing documented conditions. Due to age of equipment, R22 refrigerant type, extent of previous rodent damage, and current corrosion issues, recommended system replacement as most cost-effective solution versus ongoing repairs.
Responded to no cooling call on 20-year-old Comfortmaker R22 system with history of rodent damage from previous season that had caused grounded 24V wiring and corroded dual capacitor and contactor. Upon arrival, accessed condenser unit and documented extensive interior corrosion and rust throughout cabinet from prolonged moisture exposure. Inspected electrical connections and wiring harness at contactor and terminal block, noting deteriorated condition of components. Photographed damaged areas showing rust accumulation at base of unit and around connection points, as well as exterior disconnect and utility boxes. Homeowner authorized remotely via phone after reviewing documented conditions. Due to age of equipment, R22 refrigerant type, extent of previous rodent damage, and current corrosion issues, recommended system replacement as most cost-effective solution versus ongoing repairs.
Aidan W.
Aidan W. Checked in
Responded to no cooling call on 20-year-old Comfortmaker R22 system with history of rodent damage from previous season that had caused grounded 24V wiring and corroded dual capacitor and contactor. Upon arrival, accessed condenser unit and documented extensive interior corrosion and rust throughout cabinet from prolonged moisture exposure. Inspected electrical connections and wiring harness at contactor and terminal block, noting deteriorated condition of components. Photographed damaged areas showing rust accumulation at base of unit and around connection points, as well as exterior disconnect and utility boxes. Homeowner authorized remotely via phone after reviewing documented conditions. Due to age of equipment, R22 refrigerant type, extent of previous rodent damage, and current corrosion issues, recommended system replacement as most cost-effective solution versus ongoing repairs.
West Olive, MI 49460
Completed full air conditioning system replacement at residential property. Installed new outdoor condensing unit on existing concrete pad with proper clearances from exterior wall, secured all refrigerant line connections, and verified electrical connections to outdoor unit. Interior installation included new air handler equipment integrated with existing Luxaire furnace system in basement mechanical room, with all refrigerant lines, condensate drainage, and PVC venting properly routed and secured. System was pressure tested for leaks, evacuated, charged to manufacturer specifications, and tested through complete cooling cycle to verify proper operation of all components.
Completed full air conditioning system replacement at residential property. Installed new outdoor condensing unit on existing concrete pad with proper clearances from exterior wall, secured all refrigerant line connections, and verified electrical connections to outdoor unit. Interior installation included new air handler equipment integrated with existing Luxaire furnace system in basement mechanical room, with all refrigerant lines, condensate drainage, and PVC venting properly routed and secured. System was pressure tested for leaks, evacuated, charged to manufacturer specifications, and tested through complete cooling cycle to verify proper operation of all components.
Robert K.
Robert K. Checked in
Completed full air conditioning system replacement at residential property. Installed new outdoor condensing unit on existing concrete pad with proper clearances from exterior wall, secured all refrigerant line connections, and verified electrical connections to outdoor unit. Interior installation included new air handler equipment integrated with existing Luxaire furnace system in basement mechanical room, with all refrigerant lines, condensate drainage, and PVC venting properly routed and secured. System was pressure tested for leaks, evacuated, charged to manufacturer specifications, and tested through complete cooling cycle to verify proper operation of all components.
West Olive, MI 49460
Responded to service call for Trane air handler displaying compressor filter error code and producing warm air from vents. Upon arrival, inspected 19-year-old Trane HVAC system located in basement utility area. Verified system status via digital control panel showing active fault code. Examined air handler unit, refrigerant line connections, and associated components for proper operation. Documented equipment condition and installation with photographic evidence showing copper refrigerant lines with insulation, wall-mounted electrical components, and overall system configuration. System evaluated for airflow restrictions, filter status, and compressor functionality to diagnose warm air issue and resolve error code condition.
Responded to service call for Trane air handler displaying compressor filter error code and producing warm air from vents. Upon arrival, inspected 19-year-old Trane HVAC system located in basement utility area. Verified system status via digital control panel showing active fault code. Examined air handler unit, refrigerant line connections, and associated components for proper operation. Documented equipment condition and installation with photographic evidence showing copper refrigerant lines with insulation, wall-mounted electrical components, and overall system configuration. System evaluated for airflow restrictions, filter status, and compressor functionality to diagnose warm air issue and resolve error code condition.
Brad K.
Brad K. Checked in
Responded to service call for Trane air handler displaying compressor filter error code and producing warm air from vents. Upon arrival, inspected 19-year-old Trane HVAC system located in basement utility area. Verified system status via digital control panel showing active fault code. Examined air handler unit, refrigerant line connections, and associated components for proper operation. Documented equipment condition and installation with photographic evidence showing copper refrigerant lines with insulation, wall-mounted electrical components, and overall system configuration. System evaluated for airflow restrictions, filter status, and compressor functionality to diagnose warm air issue and resolve error code condition.
West Olive, MI 49460
West Olive, MI - Completed annual cooling maintenance on 2018 EnergiAir system. Performed comprehensive tune-up including inspection of air handler, refrigerant lines, condensate drainage, and electrical connections. All components operating within manufacturer specifications, system documentation photographed for records.
Gavin W.
Gavin W. Checked in
Completed annual cooling maintenance on 2018 EnergiAir system. Performed comprehensive tune-up including inspection of air handler, refrigerant lines, condensate drainage, and electrical connections. All components operating within manufacturer specifications, system documentation photographed for records.
West Olive, MI 49460
Responded to emergency call after utility company issued pink tag for significant gas leak at generator union connection. Inspected 2-year-old Generac unit and identified leaking union fitting on gas supply line. Tightened connection, applied pipe dope to threads, and pressure tested system to verify leak was eliminated and all connections were secure per manufacturer specifications.
Responded to emergency call after utility company issued pink tag for significant gas leak at generator union connection. Inspected 2-year-old Generac unit and identified leaking union fitting on gas supply line. Tightened connection, applied pipe dope to threads, and pressure tested system to verify leak was eliminated and all connections were secure per manufacturer specifications.
Andrew S.
Andrew S. Checked in
Responded to emergency call after utility company issued pink tag for significant gas leak at generator union connection. Inspected 2-year-old Generac unit and identified leaking union fitting on gas supply line. Tightened connection, applied pipe dope to threads, and pressure tested system to verify leak was eliminated and all connections were secure per manufacturer specifications.
West Olive, MI 49460
Responded to no heat call on first floor with newly installed EnergiAir furnace system. Upon arrival, performed comprehensive system diagnostics and inspected ductwork distribution throughout first floor living areas. Verified thermostat operation, checked air handler blower motor function, and tested limit switches and safety controls. Examined supply and return air vents in main living space and confirmed proper airflow from ceiling registers. System demonstrated partial heating capability but inadequate temperature delivery to first floor zone. Identified and resolved airflow restriction issue affecting heat distribution to living areas. Cycled system through multiple heating calls to verify proper operation and consistent temperature delivery to all first floor rooms. Confirmed furnace ignition sequence, burner operation, and heat exchanger performance within manufacturer specifications. System now providing adequate heat to first floor with proper temperature rise across heat exch
Responded to no heat call on first floor with newly installed EnergiAir furnace system. Upon arrival, performed comprehensive system diagnostics and inspected ductwork distribution throughout first floor living areas. Verified thermostat operation, checked air handler blower motor function, and tested limit switches and safety controls. Examined supply and return air vents in main living space and confirmed proper airflow from ceiling registers. System demonstrated partial heating capability but inadequate temperature delivery to first floor zone. Identified and resolved airflow restriction issue affecting heat distribution to living areas. Cycled system through multiple heating calls to verify proper operation and consistent temperature delivery to all first floor rooms. Confirmed furnace ignition sequence, burner operation, and heat exchanger performance within manufacturer specifications. System now providing adequate heat to first floor with proper temperature rise across heat exch
Mitch H.
Mitch H. Checked in
Responded to no heat call on first floor with newly installed EnergiAir furnace system. Upon arrival, performed comprehensive system diagnostics and inspected ductwork distribution throughout first floor living areas. Verified thermostat operation, checked air handler blower motor function, and tested limit switches and safety controls. Examined supply and return air vents in main living space and confirmed proper airflow from ceiling registers. System demonstrated partial heating capability but inadequate temperature delivery to first floor zone. Identified and resolved airflow restriction issue affecting heat distribution to living areas. Cycled system through multiple heating calls to verify proper operation and consistent temperature delivery to all first floor rooms. Confirmed furnace ignition sequence, burner operation, and heat exchanger performance within manufacturer specifications. System now providing adequate heat to first floor with proper temperature rise across heat exch
West Olive, MI 49460
Completed annual cooling maintenance on 2015 EnergiAir system under active warranty coverage. Performed comprehensive inspection of evaporator coil assembly, verified proper refrigerant flow through serpentine coil configuration, and confirmed insulation integrity within air handler chamber. Conducted electrical diagnostics using digital multimeter on TITAN PRO capacitor (model TRCFD450), obtaining readings of 35.15 microfarads which fall within acceptable operating parameters for the compressor circuit. All electrical connections, terminals, and wire routing inspected and found secure with no signs of degradation or overheating.
Completed annual cooling maintenance on 2015 EnergiAir system under active warranty coverage. Performed comprehensive inspection of evaporator coil assembly, verified proper refrigerant flow through serpentine coil configuration, and confirmed insulation integrity within air handler chamber. Conducted electrical diagnostics using digital multimeter on TITAN PRO capacitor (model TRCFD450), obtaining readings of 35.15 microfarads which fall within acceptable operating parameters for the compressor circuit. All electrical connections, terminals, and wire routing inspected and found secure with no signs of degradation or overheating.
Matt H.
Matt H. Checked in
Completed annual cooling maintenance on 2015 EnergiAir system under active warranty coverage. Performed comprehensive inspection of evaporator coil assembly, verified proper refrigerant flow through serpentine coil configuration, and confirmed insulation integrity within air handler chamber. Conducted electrical diagnostics using digital multimeter on TITAN PRO capacitor (model TRCFD450), obtaining readings of 35.15 microfarads which fall within acceptable operating parameters for the compressor circuit. All electrical connections, terminals, and wire routing inspected and found secure with no signs of degradation or overheating.
West Olive, MI 49460
Responded to emergency plumbing leak at kitchen sink. Upon arrival, identified active leak at shut-off valve union connection under sink. Shut off water supply, removed faulty union fitting, cleaned threads, and installed new compression union with proper sealing. Tested system under full pressure to confirm leak was eliminated. Inspected surrounding plumbing connections and water heater installation for additional issues. No further leaks detected upon completion.
Responded to emergency plumbing leak at kitchen sink. Upon arrival, identified active leak at shut-off valve union connection under sink. Shut off water supply, removed faulty union fitting, cleaned threads, and installed new compression union with proper sealing. Tested system under full pressure to confirm leak was eliminated. Inspected surrounding plumbing connections and water heater installation for additional issues. No further leaks detected upon completion.
Quinton M.
Quinton M. Checked in
Responded to emergency plumbing leak at kitchen sink. Upon arrival, identified active leak at shut-off valve union connection under sink. Shut off water supply, removed faulty union fitting, cleaned threads, and installed new compression union with proper sealing. Tested system under full pressure to confirm leak was eliminated. Inspected surrounding plumbing connections and water heater installation for additional issues. No further leaks detected upon completion.
West Olive, MI 49460
Responded to no heat call where furnace was running but not producing flame. Upon inspection, tested system operation and confirmed unit was cycling but failing to ignite. Performed diagnostic testing with multimeter showing reading of 99.9 ohms, indicating flame sensor was reading out of acceptable range due to carbon buildup and contamination. Removed and cleaned flame sensor rod to restore proper conductivity. Verified ignition sequence, confirmed flame establishment and flame proving circuit functionality. System restored to normal heating operation with proper burner ignition and sustained flame.
Responded to no heat call where furnace was running but not producing flame. Upon inspection, tested system operation and confirmed unit was cycling but failing to ignite. Performed diagnostic testing with multimeter showing reading of 99.9 ohms, indicating flame sensor was reading out of acceptable range due to carbon buildup and contamination. Removed and cleaned flame sensor rod to restore proper conductivity. Verified ignition sequence, confirmed flame establishment and flame proving circuit functionality. System restored to normal heating operation with proper burner ignition and sustained flame.
Andrew S.
Andrew S. Checked in
Responded to no heat call where furnace was running but not producing flame. Upon inspection, tested system operation and confirmed unit was cycling but failing to ignite. Performed diagnostic testing with multimeter showing reading of 99.9 ohms, indicating flame sensor was reading out of acceptable range due to carbon buildup and contamination. Removed and cleaned flame sensor rod to restore proper conductivity. Verified ignition sequence, confirmed flame establishment and flame proving circuit functionality. System restored to normal heating operation with proper burner ignition and sustained flame.
West Olive, MI 49460
West Olive, MI - Responded to electrical service call for nicked wire in garage damaged during drywall removal. Located affected wiring in exposed wall cavity near junction box, assessed damage to conductor insulation, and performed proper repair using approved splicing methods within code-compliant junction box. Verified circuit integrity, tested for proper grounding and continuity, and confirmed safe operation of affected circuit. Documented conditions with photographs showing spray foam insulated area, existing junction box, and surrounding infrastructure including copper piping.
Ed V.
Ed V. Checked in
Responded to electrical service call for nicked wire in garage damaged during drywall removal. Located affected wiring in exposed wall cavity near junction box, assessed damage to conductor insulation, and performed proper repair using approved splicing methods within code-compliant junction box. Verified circuit integrity, tested for proper grounding and continuity, and confirmed safe operation of affected circuit. Documented conditions with photographs showing spray foam insulated area, existing junction box, and surrounding infrastructure including copper piping.
West Olive, MI 49460
West Olive, MI - Responded to emergency call for failed sump pump causing water backup in basement. Upon arrival, assessed sump pump system and determined pump failure was preventing proper drainage. Replaced failed sump pump unit, tested operation to ensure proper water discharge, and verified system functionality to prevent further water intrusion into basement space.
Evan I.
Evan I. Checked in
Responded to emergency call for failed sump pump causing water backup in basement. Upon arrival, assessed sump pump system and determined pump failure was preventing proper drainage. Replaced failed sump pump unit, tested operation to ensure proper water discharge, and verified system functionality to prevent further water intrusion into basement space.
West Olive, MI 49460
West Olive, MI - Completed annual cooling system tune-up on EnergiAir air handler unit (model year 2011, warranty through 05-2035). Performed standard maintenance inspection of HVAC equipment in mechanical room, verified proper operation of all components, checked electrical connections at junction box, and inspected condensate drainage system and associated PVC piping. Equipment found to be in clean, well-maintained condition with no issues identified.
Gavin W.
Gavin W. Checked in
Completed annual cooling system tune-up on EnergiAir air handler unit (model year 2011, warranty through 05-2035). Performed standard maintenance inspection of HVAC equipment in mechanical room, verified proper operation of all components, checked electrical connections at junction box, and inspected condensate drainage system and associated PVC piping. Equipment found to be in clean, well-maintained condition with no issues identified.
West Olive, MI 49460
Performed comprehensive 10-year tune-up on Generac generator unit. Adjusted valve lash to manufacturer specifications and completed full system inspection. Unit operational and running within normal parameters upon completion.
Performed comprehensive 10-year tune-up on Generac generator unit. Adjusted valve lash to manufacturer specifications and completed full system inspection. Unit operational and running within normal parameters upon completion.
Brent A.
Brent A. Checked in
Performed comprehensive 10-year tune-up on Generac generator unit. Adjusted valve lash to manufacturer specifications and completed full system inspection. Unit operational and running within normal parameters upon completion.
West Olive, MI 49460
Start Saving Today With

Membership Perks

Start Saving Today With

Membership Perks

What To Expect

Discover The Vredevoogd Difference

24/7 Emergency HVAC Service

HVAC emergencies can happen on nights, weekends, and holidays, so our phones are always open to take calls!

100% Satisfaction Guarantee

The Vredevoogd team is dedicated to a promise of 100% client satisfaction with every service we perform.

Background-Checked Technicians

Our employees are background-checked, ensuring you have peace of mind when they enter your home.

Free Estimates

You can expect free, honest, and accurate estimates on replacements and financing options to make fully informed HVAC or plumbing decisions for your home.

Financing Available

We offer various financing options to make our services affordable and accessible for Michigan homeowners.

A+ on BBB

With an A+ BBB rating, Vredevoogd continues to build trust between our company and customers.

24/7 Emergency HVAC Service

HVAC emergencies can happen on nights, weekends, and holidays, so our phones are always open to take calls!

100% Satisfaction Guarantee

The Vredevoogd team is dedicated to a promise of 100% client satisfaction with every service we perform.

Background-Checked Technicians

Our employees are background-checked, ensuring you have peace of mind when they enter your home.

Free Estimates

You can expect free, honest, and accurate estimates on replacements and financing options to make fully informed HVAC or plumbing decisions for your home.

Financing Available

We offer various financing options to make our services affordable and accessible for Michigan homeowners.

A+ on BBB

With an A+ BBB rating, Vredevoogd continues to build trust between our company and customers.

Our Reviews

See What Your Neighbors Are Saying.

Completely professional. Did an outstanding job meeting our needs and time frame. Didn't try to push us to get more than we needed or could afford but made sure we had the right fit for our home.

Amanda S.

Portage, MI

Amanda S.

Portage, MI

Very impressed with Vredevoogd Heating and Cooling. I met three of their techs and all of them were wonderful. We had the air conditioning and furnace installed in one day and they had our house cooled and ready to go by 1pm. Very polite, hard working and honest. Would highly recommend.

Emilee S.

Comstock Park, MI

Emilee S.

Comstock Park, MI

We were having issues with low hot water pressure on/off for a year; lots of sediment in tank. Hot water tank and furnace 20 years old. Asked technician to take a look at the furnace to see if there were any problems and he showed me several failures including large cracks. He told me all the…

Rebecca E.

Holland, MI

Rebecca E.

Holland, MI

I had David G’s help this afternoon locating a leak source, and going over regular maintenance required for my home (I’m an inexperienced first-time owner). I cannot thank him enough for his courteous help, thoughtful advice & time. I look forward to using Vredevoogd’s services in the future!.

Jane O.

Kalamazoo, MI

Jane O.

Kalamazoo, MI

Ryen was PHENOMENAL!!! He explained thoroughly the functioning of my system. He also saved me tons of money in repair along with replacement. Hands down they have truly earned my business!!!! I couldn’t be happier with my visit.

Karenia R.

Lansing, MI

Karenia R.

Lansing, MI